Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Microbiol Spectr ; 10(2): e0250721, 2022 04 27.
Article in English | MEDLINE | ID: covidwho-1779319

ABSTRACT

The multiplex capabilities of the new xMAP INTELLIFLEX DR-SE flow analyzer were explored by modifying a serological assay previously used to characterize the IgG antibody to infection with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The goal was to examine the instrument's performance and to simultaneously measure IgM and IgG antibody responses against multiple SARS-CoV-2 antigens in a single assay. Specific antibodies against the SARS-CoV-2 spike (S), receptor binding domain (RBD), and nucleocapsid (N) proteins were investigated in 310 symptomatic case patients using a fluorescent microsphere immunoassay and simultaneous detection of IgM and IgG. Neutralization potential was studied using the addition of soluble angiotensin-converting enzyme 2 (ACE2) to block antibody binding. A profile extending to 180 days from symptom onset (DFSO) was described for antibodies specific to each viral antigen. Generally, IgM levels peaked and declined rapidly ∼3-4 weeks following infection, whereas S- and RBD-specific IgG plateaued at 80 DFSO. ACE2 more effectively prevented IgM and IgG binding in convalescent cases > 30 DFSO, suggesting those antibodies had greater neutralization potential. This work highlighted the multiplex and multi-analyte potential of the xMAP INTELLIFLEX DR-SE, and provided further evidence for antigen-specific IgM and IgG trajectories in acute and convalescent cases. IMPORTANCE The xMAP INTELLIFLEX DR-SE enabled simultaneous and semi-quantitative detection of both IgM and IgG to three different SARS-CoV-2 antigens in a single assay. The assay format is advantageous for rapid and medium-throughput profiling using a small volume of specimen. The xMAP INTELLIFLEX DR-SE technology demonstrated the potential to include numerous SARS-CoV-2 antigens; future work could incorporate multiple spike protein variants in a single assay. This could be an important feature for assessing the serological response to emerging variants of SARS-CoV-2.


Subject(s)
COVID-19 , SARS-CoV-2 , Angiotensin-Converting Enzyme 2 , Antibodies, Neutralizing , Antibodies, Viral , COVID-19/diagnosis , Humans , Immunoglobulin G , Immunoglobulin M , Nucleocapsid , Spike Glycoprotein, Coronavirus
2.
J Infect Dis ; 226(3): 474-484, 2022 08 26.
Article in English | MEDLINE | ID: covidwho-1758749

ABSTRACT

BACKGROUND: A protective antibody response to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is crucial to decrease morbidity and mortality from severe coronavirus disease 2019 (COVID-19) disease. The effects of preexisting anti-human coronavirus (HCoV) antibodies on the SARS-CoV-2-specific immunoglobulin G (IgG) responses and severity of disease are currently unclear. METHODS: We profiled anti-spike (S), S1, S2, and receptor-binding domain IgG antibodies against SARS-CoV-2 and 6 HCoVs using a multiplex assay (mPLEX-CoV) with serum samples from SARS-CoV-2 infected (n = 155) and pre-COVID-19 (n = 188) cohorts. RESULTS: COVID-19 subjects showed significantly increased anti-S SARS-CoV-2 IgG levels that were highly correlated with IgG antibodies against OC43 and HKU1 S proteins. However, OC43 and HKU1 anti-S antibodies in pre-COVID-19 era sera did not cross-react with SARS-CoV-2. Unidirectional cross-reactive antibodies elicited by SARS-CoV-2 infection were distinct from the bidirectional cross-reactive antibodies recognizing homologous strains RaTG13 and SARS-CoV-1. High anti-OC43 and anti-S2 antibody levels were associated with both a rapid anti-SARS-CoV-2 antibody response and increased disease severity. Subjects with increased sequential organ failure assessment (SOFA) scores developed a higher ratio of S2- to S1-reactive antibodies. CONCLUSIONS: Early and rapid emergence of OC43 S- and S2-reactive IgG after SARS-CoV-2 infection correlates with COVID-19 disease severity.


Subject(s)
COVID-19 , Antibodies, Viral , Cross Reactions , Humans , Immunoglobulin G , SARS-CoV-2 , Severity of Illness Index , Spike Glycoprotein, Coronavirus
4.
Clin Chem ; 67(9): 1188-1200, 2021 09 01.
Article in English | MEDLINE | ID: covidwho-1381002

ABSTRACT

BACKGROUND: The clinical laboratory continues to play a critical role in managing the coronavirus pandemic. Numerous US Food and Drug Administration emergency use authorization (EUA) and laboratory-developed test (LDT) serologic assays have become available. The performance characteristics of these assays and their clinical utility continue to be defined in real time during this pandemic. The AACC convened a panel of experts from clinical chemistry, microbiology, and immunology laboratories; the in vitro diagnostics industry; and regulatory agencies to provide practical recommendations for implementation and interpretation of these serologic tests in clinical laboratories. CONTENT: The currently available EUA serologic tests and platforms, information on assay design, antibody classes including neutralizing antibodies, and the humoral immune responses to SARS-CoV-2 are discussed. Verification and validation of EUA and LDT assays are described, along with a quality management approach. Four indications for serologic testing are outlined. Recommendations for result interpretation, reporting comments, and the role of orthogonal testing are also presented. SUMMARY: This document aims to provide a comprehensive reference for laboratory professionals and healthcare workers to appropriately implement SARS-CoV-2 serologic assays in the clinical laboratory and to interpret test results during this pandemic. Given the more frequent occurrence of outbreaks associated with either vector-borne or respiratory pathogens, this document will be a useful resource in planning for similar scenarios in the future.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Laboratories/standards , SARS-CoV-2/isolation & purification , Antibodies, Viral/biosynthesis , Antibodies, Viral/immunology , COVID-19/virology , Humans , SARS-CoV-2/immunology
5.
Clin Lab Med ; 40(4): xiii-xiv, 2020 12.
Article in English | MEDLINE | ID: covidwho-892828
6.
Acad Pathol ; 8: 23742895211006818, 2021.
Article in English | MEDLINE | ID: covidwho-1225750

ABSTRACT

The COVID-19 pandemic, caused by severe acute respiratory syndrome coronavirus 2, created an unprecedented need for comprehensive laboratory testing of populations, in order to meet the needs of medical practice and to guide the management and functioning of our society. With the greater New York metropolitan area as an epicenter of this pandemic beginning in March 2020, a consortium of laboratory leaders from the assembled New York academic medical institutions was formed to help identify and solve the challenges of deploying testing. This report brings forward the experience of this consortium, based on the real-world challenges which we encountered in testing patients and in supporting the recovery effort to reestablish the health care workplace. In coordination with the Greater New York Hospital Association and with the public health laboratory of New York State, this consortium communicated with state leadership to help inform public decision-making addressing the crisis. Through the length of the pandemic, the consortium has been a critical mechanism for sharing experience and best practices in dealing with issues including the following: instrument platforms, sample sources, test performance, pre- and post-analytical issues, supply chain, institutional testing capacity, pooled testing, biospecimen science, and research. The consortium also has been a mechanism for staying abreast of state and municipal policies and initiatives, and their impact on institutional and laboratory operations. The experience of this consortium may be of value to current and future laboratory professionals and policy-makers alike, in dealing with major events that impact regional laboratory services.

7.
J Vis Exp ; (170)2021 04 06.
Article in English | MEDLINE | ID: covidwho-1202107

ABSTRACT

The COVID-19 pandemic has underscored the need for rapid high-throughput methods for sensitive and specific serological detection of infection with novel pathogens, such as SARS-CoV-2. Multiplex serological testing can be particularly useful because it can simultaneously analyze antibodies to multiple antigens that optimizes pathogen coverage, and controls for variability in the organism and the individual host response. Here we describe a SARS-CoV-2 IgG 3-plex fluorescent microsphere-based assay that can detect both IgM and IgG antibodies to three major SARS-CoV-2 antigens-the spike (S) protein, spike angiotensin-converting enzyme-2 (ACE2) receptor-binding domain (RBD), and nucleocapsid (Nc). The assay was shown to have comparable performance to a SARS-CoV-2 reference assay for IgG in serum obtained at ≥21 days from symptom onset but had higher sensitivity with samples collected at ≤5 days from symptom onset. Further, using soluble ACE2 in a neutralization assay format, inhibition of antibody binding was demonstrated for S and RBD.


Subject(s)
Antibodies, Neutralizing/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Flow Cytometry/methods , Immunoglobulin G/blood , Immunoglobulin M/blood , SARS-CoV-2/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , COVID-19/blood , COVID-19/immunology , Humans , Spike Glycoprotein, Coronavirus/immunology
8.
J Clin Microbiol ; 59(2)2021 01 21.
Article in English | MEDLINE | ID: covidwho-1041375

ABSTRACT

The coronavirus disease 2019 (COVID-19) pandemic has highlighted the challenges inherent to the serological detection of a novel pathogen such as severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Serological tests can be used diagnostically and for surveillance, but their usefulness depends on their throughput, sensitivity, and specificity. Here, we describe a multiplex fluorescent microsphere-based assay, 3Flex, that can detect antibodies to three major SARS-CoV-2 antigens-spike (S) protein, the spike ACE2 receptor-binding domain (RBD), and nucleocapsid (NP). Specificity was assessed using 213 prepandemic samples. Sensitivity was measured and compared to that of the Abbott Architect SARS-CoV-2 IgG assay using serum samples from 125 unique patients equally binned (n = 25) into 5 time intervals (≤5, 6 to 10, 11 to 15, 16 to 20, and ≥21 days from symptom onset). With samples obtained at ≤5 days from symptom onset, the 3Flex assay was more sensitive (48.0% versus 32.0%), but the two assays performed comparably using serum obtained ≥21 days from symptom onset. A larger collection (n = 534) of discarded sera was profiled from patients (n = 140) whose COVID-19 course was characterized through chart review. This revealed the relative rise, peak (S, 23.8; RBD, 23.6; NP, 16.7 [in days from symptom onset]), and decline of the antibody response. Considerable interperson variation was observed with a subset of extensively sampled intensive care unit (ICU) patients. Using soluble ACE2, inhibition of antibody binding was demonstrated for S and RBD, and not for NP. Taking the data together, this study described the performance of an assay built on a flexible and high-throughput serological platform that proved adaptable to the emergence of a novel infectious agent.


Subject(s)
COVID-19 Serological Testing/methods , COVID-19/diagnosis , Microspheres , SARS-CoV-2/isolation & purification , Aged , Aged, 80 and over , Angiotensin-Converting Enzyme 2 , Antibodies, Neutralizing/blood , Antibodies, Viral/blood , COVID-19/blood , COVID-19/pathology , Coronavirus Nucleocapsid Proteins/immunology , Female , Fluoroimmunoassay , Humans , Immunoglobulin G/blood , Kinetics , Male , Middle Aged , Phosphoproteins/immunology , SARS-CoV-2/immunology , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus/chemistry , Spike Glycoprotein, Coronavirus/immunology , Spike Glycoprotein, Coronavirus/metabolism
10.
Clin Lab Med ; 40(4): 603-614, 2020 12.
Article in English | MEDLINE | ID: covidwho-845585

ABSTRACT

The entire spectrum of diagnostic testing, from reagent supply to test performance, has been a major focus during the coronavirus disease 2019 (COVID-19) pandemic. The hope for serologic testing is that it will provide both epidemiologic information about seroprevalence as well as individual information about previous infection. This information is particularly helpful for high-risk individuals who may be outside of the viral shedding window, such as children with suspected multisystem inflammatory syndrome. It is not yet understood whether serologic testing can be interpreted in terms of protective immunity. These concerns must be addressed using highly sensitive and specific tests.


Subject(s)
Betacoronavirus , Clinical Laboratory Techniques/methods , Coronavirus Infections , Pandemics , Pneumonia, Viral , Seroepidemiologic Studies , Betacoronavirus/immunology , Betacoronavirus/isolation & purification , COVID-19 , COVID-19 Testing , Coronavirus Infections/diagnosis , Coronavirus Infections/epidemiology , Coronavirus Infections/immunology , Coronavirus Infections/prevention & control , Humans , Immunity, Humoral/immunology , Pandemics/prevention & control , Pneumonia, Viral/epidemiology , Pneumonia, Viral/immunology , Pneumonia, Viral/prevention & control , Protective Factors , SARS-CoV-2 , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL